Switched 3/16" dia vinyl tubing to the correct color. Blue vinyl tubing was incorrectly installed in the Total Energy probe port. Switched it to green. Looked at methods and positions to secure the pitot and TE lines from the tail into the 3002 AL tubing lines. Will likely use an epoxied on stud to secure a pair of clamps for the vinyl tubing.
Installed a BNC fitting to the RG59 antenna wire for the ELT.